Reference case

Split electrodes for electrical-conductivity-based tissue discrimination

Category

Case summary

At a glance

This work presents a method to minimize the inadvertent cutting of tissues in surgeries involving bone drilling. We present electrical impedance measurements as an assistive technology to image-guided surgery to achieve online guidance. Proposed concept is to identify and localize the landmarks via impedance measurements and then use this information to superimpose the estimated drilling […]

Full reference article

This work presents a method to minimize the inadvertent cutting of tissues in surgeries involving bone drilling. We present electrical impedance measurements as an assistive technology to image-guided surgery to achieve online guidance. Proposed concept is to identify and localize the landmarks via impedance measurements and then use this information to superimpose the estimated drilling trajectory on the offline maps obtained by pre-operative imaging. To this end., we propose an asymmetric electrode geometry., split electrodes., capable of distinguishing impedance variations as a function of rotation angle. The feasibility of the proposed approach is verified with numerical analysis. A probe with stainless steel electrodes has been fabricated and tested with a technical phantom. Although the results are impacted by a non-ideality in the phantom., we could show that the variation of impedance as a function of rotation angle can be used to localize the regions with different impedivities. Clinical Relevance- Presented approach may be used to minimize the inadvertent cutting of tissues in surgeries involving bone drilling.

Learn more about the ISX-3 impedance analyzer

Class-Leading Impedance analyzer, the Sciospec ISX-3

Or check out the Medical Research ISX-3

In this section

Table of Contents

Reference facts

Application area

Category

Published

June 26, 2024

Tags

Key takeaway
In this study, we established an ultrasensitive electrochemical immunosensor based on the gold nanoparticles-enhanced tyramide signal amplification (AuNPs-TSA) for the detection of procalcitonin (PCT, for discriminating …
Related references

You may also like

Bioimpedance as a tool in cardiac resyncronisation therapy

Electrical Impedance to Assess Facial Nerve Proximity During Robotic Cochlear Implantation

Gene-sensor on the Basis of Magnetic Immobilization and Bioimpedance Measurements: a proof of concept

Discuss your application

Want to build something like this?

Talk to our application engineers about scoping a similar setup for your team.

Get in touch with us

Headquarters

Sciospec Scientific Instruments GmbH Leipziger Str. 43b 04828 Bennewitz, Germany

Open in Google Maps

Get in touch with us

We typically reply within one business day.