Electrical Impedance to Assess Facial Nerve Proximity During Robotic Cochlear Implantation

Category

Application

Bioanalytics

Case summary

At a glance

Needle guidance study with a modified ISX-3

Full reference article

Reported studies pertaining to needle guidance suggest that tissue impedance available from neuromonitoring systems can be used to discriminate nerve tissue proximity. In this pilot study, the existence of a relationship between intraoperative electrical impedance and tissue density, estimated from computer tomography (CT) images, is evaluated in the mastoid bone of in vivo sheep. In five subjects, nine trajectories were drilled using an image-guided surgical robot. Per trajectory, five measurement points near the facial nerve were accessed and electrical impedance was measured (≤1 KHz) using a multipolar electrode probe. Micro-CT was used postoperatively to measure the distances from the drilled trajectories to the facial nerve. Tissue density was determined from coregistered preoperative CT images and, following sensitivity field modeling of the measuring tip, tissue resistivity was calculated. The relationship between impedance and density was determined for 29 trajectories passing or intersecting the facial nerve. A monotonic decrease in impedance magnitude was observed in all trajectories with a drill axis intersecting the facial nerve. Mean tissue densities intersecting with the facial nerve (971-1161 HU) were different (p <;0.01) from those along safe trajectories passing the nerve (1194-1449 HU). However, mean resistivity values of trajectories intersecting the facial nerve (14-24 Ωm) were similar to those of safe passing trajectories (17-23 Ωm). The determined relationship between tissue density and electrical impedance during neuromonitoring of the facial nerve suggests that impedance spectroscopy may be used to increase the accuracy of tissue discrimination, and ultimately improve nerve safety distance assessment in the future.

In this section

Table of Contents

Reference facts

Application area

Bioanalytics

Category

Published

April 30, 2020

Tags

Key takeaway
Needle guidance study with a modified ISX-3
Related references

You may also like

Bioimpedance as a tool in cardiac resyncronisation therapy

Gene-sensor on the Basis of Magnetic Immobilization and Bioimpedance Measurements: a proof of concept

Impedance detection of the electrical resistivity of the wound tissue around deep brain stimulation electrodes permits registration of the encapsulation process in a rat model

Discuss your application

Want to build something like this?

Talk to our application engineers about scoping a similar setup for your team.

Get in touch with us

Headquarters

Sciospec Scientific Instruments GmbH Leipziger Str. 43b 04828 Bennewitz, Germany

Open in Google Maps

Get in touch with us

We typically reply within one business day.