Conformable and robust microfluidic force sensors to enable precision joint replacement surgery

Category

Application

Medical & healthcare

Case summary

At a glance

Balancing forces within weight-bearing joints such as the hip during joint replacement is essential for implant longevity. Minimising implant failure and the corresponding need for expensive and difficult revision surgery is vital to both improve the quality of life of the patient and lighten the burden on overstretched healthcare systems. However, balancing forces during total […]

Full reference article
Balancing forces within weight-bearing joints such as the hip during joint replacement is essential for implant longevity. Minimising implant failure and the corresponding need for expensive and difficult revision surgery is vital to both improve the quality of life of the patient and lighten the burden on overstretched healthcare systems. However, balancing forces during total hip replacements is currently subjective and entirely dependent on surgical skill, as there are no sensors currently on the market that are capable of providing quantitative force feedback within the small and complex geometry of the hip joint. Here, we solve this unmet clinical need by presenting a thin and conformable microfluidic force sensor, which is compatible with the standard surgical procedure. The sensors are fabricated via additive manufacturing, using a combination of 3D and aerosol-jet printing. We optimised the design using finite element modelling, then incorporated and calibrated our sensors in a 3D printed model hip implant. Using a bespoke testing rig, we demonstrated high sensitivity at typical forces experienced following implantation of hip replacements. We anticipate that these sensors will aid soft tissue balancing and implant positioning, thereby increasing the longevity of hip replacements. These sensors thus represent a powerful new surgical tool for a range of orthopaedic procedures where balancing forces is crucial.

Learn more about the ISX-3 impedance analyzer

Class-Leading Impedance analyzer, the Sciospec ISX-3

In this section

Table of Contents

Reference facts

Application area

Medical & healthcare

Category

Published

June 26, 2024

Tags

Key takeaway
Balancing forces within weight-bearing joints such as the hip during joint replacement is essential for implant longevity. Minimising implant failure and the corresponding need for expensive and difficult revision surger…
Related references

You may also like

Bioimpedance as a tool in cardiac resyncronisation therapy

Electrical Impedance to Assess Facial Nerve Proximity During Robotic Cochlear Implantation

Gene-sensor on the Basis of Magnetic Immobilization and Bioimpedance Measurements: a proof of concept

Discuss your application

Want to build something like this?

Talk to our application engineers about scoping a similar setup for your team.

Get in touch with us

Headquarters

Sciospec Scientific Instruments GmbH Leipziger Str. 43b 04828 Bennewitz, Germany

Open in Google Maps

Get in touch with us

We typically reply within one business day.