Reference case

Electrical Impedance Properties of Deep Brain Stimulation Electrodes during Long-Term In-Vivo Stimulation in the Parkinson Model of the Rat

Category

Application

Bioanalytics

Case summary

At a glance

Deep brain stimulation (DBS) is an invasive therapeutic option for patients with Parkinson’s disease (PD) but the mechanisms behind it are not yet fully understood. Animal models are essential for basic DBS research, because cell based in-vitro techniques are not complex enough. However, the geometry difference between rodents and humans implicates transfer problems of the […]

Full reference article

Deep brain stimulation (DBS) is an invasive therapeutic option for patients with Parkinson’s disease (PD) but the mechanisms behind it are not yet fully understood. Animal models are essential for basic DBS research, because cell based in-vitro techniques are not complex enough. However, the geometry difference between rodents and humans implicates transfer problems of the stimulation conditions. For rodents, the development of miniaturized mobile stimulators and adapted electrodes are desirable. We implanted uni- and bipolar platinum/iridium electrodes in rats and were able to establish chronical instrumentation of freely moving rats (3 weeks). We measured the impedance of unipolar electrodes in-vivo to characterize the influence of electrochemical processes at the electrode-tissue interface. During the encapsulation process, the real part of the electrode impedance at 10 kHz doubled after 12 days and increased almost 10 times after 22 days. An outlook is given on the quantification of the DBS effect by sensorimotor behavioral tests
In this section

Table of Contents

Reference facts

Application area

Bioanalytics

Category

Published

July 9, 2020

Tags

Key takeaway
Deep brain stimulation (DBS) is an invasive therapeutic option for patients with Parkinson’s disease (PD) but the mechanisms behind it are not yet fully understood. Animal models are essential for basic DBS research, bec…
Related references

You may also like

Bioimpedance as a tool in cardiac resyncronisation therapy

Electrical Impedance to Assess Facial Nerve Proximity During Robotic Cochlear Implantation

Gene-sensor on the Basis of Magnetic Immobilization and Bioimpedance Measurements: a proof of concept

Discuss your application

Want to build something like this?

Talk to our application engineers about scoping a similar setup for your team.

Get in touch with us

Headquarters

Sciospec Scientific Instruments GmbH Leipziger Str. 43b 04828 Bennewitz, Germany

Open in Google Maps

Get in touch with us

We typically reply within one business day.