Reference case

Comprehensive human stem cell differentiation in a 2D and 3D mode to cardiomyocytes for long-term cultivation and multiparametric monitoring on a multimodal microelectrode array setup

Category

Application

Bioanalytics

Case summary

At a glance

The ISX-3 impedance analyzer in a long-term monitoring application

Full reference article

Human pluripotent stem cell derived cardiomyocytes are a promising cell source for research and clinical applications like investigation of cardiomyopathies and therefore, identification and testing of novel therapeutics as well as for cell based therapy approaches. However, actually it´s a challenge to generate matured adult cardiomyocyte-like phenotype in a reasonable time. Moreover, there is a lack of applicable non-invasive label-free monitoring techniques providing quantitative parameters for analysing the culture stability and maturation status. In this context, we established an efficient protocol based on a combined differentiation of hiPSC in 2D cultures followed by a forced reaggregation step that leads to highly enriched (>90% cardiomyocytes) cardiomyocyte clusters. Interestingly, 3D cultures revealed an accelerated maturation as well as phenotype switch from atrial to ventricular cardiomyocytes. More strikingly using combined impedimetric and electrophysiological monitoring the high functionality and long-term stability of 3D cardiomyocyte cultures, especially in comparison to 2D cultures could be demonstrated. Additionally, chronotropic as well as QT-prolongation causing reference compounds were used for validating the cardio specific and sensitive reaction over the monitored time range of more than 100 days. Thus, the approach of multiparametric bioelectronic monitoring offers capabilities for the long-term quantitative analysis of hiPS derived cardiomyocyte culture functionality and long-term stability. Moreover, the same multiparametric bioelectronic platform can be used in combination with validated long-term stable cardiomyocyte cultures for the quantitative detection of compound induced effects. This could pave the way for more predictive in vitro chronic/repeated dose cardiotoxicity testing assays.

In this section

Table of Contents

Reference facts

Application area

Bioanalytics

Category

Published

February 1, 2024

Tags

Key takeaway
The ISX-3 impedance analyzer in a long-term monitoring application
Related references

You may also like

Bioimpedance as a tool in cardiac resyncronisation therapy

Electrical Impedance to Assess Facial Nerve Proximity During Robotic Cochlear Implantation

Gene-sensor on the Basis of Magnetic Immobilization and Bioimpedance Measurements: a proof of concept

Discuss your application

Want to build something like this?

Talk to our application engineers about scoping a similar setup for your team.

Get in touch with us

Headquarters

Sciospec Scientific Instruments GmbH Leipziger Str. 43b 04828 Bennewitz, Germany

Open in Google Maps

Get in touch with us

We typically reply within one business day.