Reference case

A thermoelectrically stabilized aluminium acoustic trap combined with attenuated total reflection infrared spectroscopy for detection of Escherichia coli in water

Category

Case summary

At a glance

Acoustic trapping is a non-contact particle manipulation method that holds great potential for performing automated assays. We demonstrate an aluminium acoustic trap in combination with attenuated total reflection Fourier-transform infrared spectroscopy (ATR-FTIR) for detection of E. coli in water. The thermal conductivity of aluminium was exploited to thermo-electrically heat and hold the acoustic trap at the desired […]

Full reference article

Acoustic trapping is a non-contact particle manipulation method that holds great potential for performing automated assays. We demonstrate an aluminium acoustic trap in combination with attenuated total reflection Fourier-transform infrared spectroscopy (ATR-FTIR) for detection of E. coli in water. The thermal conductivity of aluminium was exploited to thermo-electrically heat and hold the acoustic trap at the desired assay temperature of 37 °C. Systematic characterisation and optimisation of the acoustic trap allowed high flow rates while maintaining high acoustic trapping performance. The ATR element serves not only as a reflector for ultrasound standing wave generation but also as a sensing interface. The enzyme conversion induced by alkaline phosphatase-labelled bacteria was directly monitored in the acoustic trap using ATR-FTIR spectroscopy. Sequential injection analysis allowed automated liquid handling, including non-contact bacteria retention, washing and enzyme-substrate exchange within the acoustic trap. The presented method was able to detect E. coli concentrations as low as 1.95 × 106 bacteria per mL in 197 min. The demonstrated ultrasound assisted assay paves the way to fully automated bacteria detection devices based on acoustic trapping combined with ATR-FTIR spectroscopy.

Graphical abstract: A thermoelectrically stabilized aluminium acoustic trap combined with attenuated total reflection infrared spectroscopy for detection of Escherichia coli in water

Learn more about the ISX-3 impedance analyzer

Class-Leading Impedance analyzer, the Sciospec ISX-3

In this section

Table of Contents

Reference facts

Application area

Category

Published

June 26, 2024

Tags

Key takeaway
Acoustic trapping is a non-contact particle manipulation method that holds great potential for performing automated assays. We demonstrate an aluminium acoustic trap in combination with attenuated total reflection Fourie…
Related references

You may also like

Bioimpedance as a tool in cardiac resyncronisation therapy

Electrical Impedance to Assess Facial Nerve Proximity During Robotic Cochlear Implantation

Gene-sensor on the Basis of Magnetic Immobilization and Bioimpedance Measurements: a proof of concept

Discuss your application

Want to build something like this?

Talk to our application engineers about scoping a similar setup for your team.

Get in touch with us

Headquarters

Sciospec Scientific Instruments GmbH Leipziger Str. 43b 04828 Bennewitz, Germany

Open in Google Maps

Get in touch with us

We typically reply within one business day.