Reference case

A Clinically Feasible Electrode Array for 3D Intraoperative Electrical Impedance Tomography-Based Surgical Margin Assessment in Robot-Assisted Radical Prostatectomy

Category

Application

Medical & healthcare

Case summary

At a glance

Objective: A novel small form factor circular electrode array was designed specifically for electrical impedance tomography (EIT) based assessment of surgical margins during robot assisted radical prostatectomy (RARP). Methods: The electrode array consists of 33 gold-plated electrodes arranged within a 9.5 mm diameter circular footprint on the end of a surgical probe that can be introduced […]

Full reference article

Objective: A novel small form factor circular electrode array was designed specifically for electrical impedance tomography (EIT) based assessment of surgical margins during robot assisted radical prostatectomy (RARP). Methods: The electrode array consists of 33 gold-plated electrodes arranged within a 9.5 mm diameter circular footprint on the end of a surgical probe that can be introduced through a standard 12 mm laparoscopic port used during RARP. The electrode array contains 8 larger, low-contact impedance outer electrodes dedicated for current drive and an internal grid of 25 smaller electrodes for simultaneous voltage measurement. Separating electrode geometry by function is designed to improve current delivery, speed, and resolution while reducing hardware requirements. Results: Simulations demonstrated that 1 mm diameter hemispherical prostate cancer inclusions could be localized within regions of adipose and benign prostate tissue; 1.5 mm diameter inclusions were required for localization within muscle tissue. A 2.38 mm diameter aluminum rod in 0.2 S/m saline could be localized throughout the imaging domain with a position error of less than 2.5 mm for depths from the electrode array surface of up to 1.7 mm. Ex vivo tissue experiments with a bovine model demonstrate visual congruence of muscle and adipose tissue locations between the sample and reconstructed images. Conclusion: Simulation and experimental results indicate good detection and location of inclusions. Significance: These results suggest the proposed electrode array design can provide sufficient accuracy in the detection and localization of prostate cancer against clinically relevant background tissues for use during RARP.

Learn more about the ISX-3 impedance analyzer

Sciospec high frame rate high precision EIT instruments with 32, 64, 128 or even 256 channels
In this section

Table of Contents

Reference facts

Application area

Medical & healthcare

Category

Published

June 26, 2024

Tags

Key takeaway
Objective: A novel small form factor circular electrode array was designed specifically for electrical impedance tomography (EIT) based assessment of surgical margins during robot assisted radical prostatectomy (RARP). M…
Related references

You may also like

Time-difference phantom experiment

Mathematical model of conductive fabric-based flexible pressure sensor

Electrical impedance tomography in on-chip integrated microtubular fluidic channels

Discuss your application

Want to build something like this?

Talk to our application engineers about scoping a similar setup for your team.

Get in touch with us

Headquarters

Sciospec Scientific Instruments GmbH Leipziger Str. 43b 04828 Bennewitz, Germany

Open in Google Maps

Get in touch with us

We typically reply within one business day.