A review on reconstruction algorithms and hardware implementation in electrical impedance tomography

Category

Application

Medical & healthcare

Case summary

At a glance

The current medical imaging techniques can only be used in a few diagnostic scenarios after the development of qualitative lesions, and they frequently include the use of radiation, among other things. Electrical impedance tomography, in contrast, uses no radiation and is non-invasive. Electric impedance tomography (EIT), which has these benefits, is frequently utilized for the […]

Full reference article

The current medical imaging techniques can only be used in a few diagnostic scenarios after the development of qualitative lesions, and they frequently include the use of radiation, among other things. Electrical impedance tomography, in contrast, uses no radiation and is non-invasive. Electric impedance tomography (EIT), which has these benefits, is frequently utilized for the early stages of disease detection and treatment. This study discusses the research advancements, image reconstruction methods, hardware system design, and clinical applications of EIT in the treatment of lung disorders for the application of EIT in the treatment of lung lesions. The intricacy of EIT systems and their solutions is explained by looking at and introducing a few key components of EIT technology. This provides research ideas for future studies and confirms the technology’s extensive development prospects. The outcome demonstrates that EIT is still in a relatively early stage of development and that image reconstruction algorithms are now being utilized to improve imaging resolution. The accuracy of data collection and processing is increasing, and hardware technology is also advancing quickly. EIT is also employed in clinical settings for pathology in the bladder, brain, and lungs. Future uses of EIT in medicine have a lot of potential for real-time, long-term monitoring and early diagnosis.

Learn more about Sciospec’s EIT platform

Sciospec high frame rate high precision EIT instruments with 32, 64, 128 or even 256 channels
In this section

Table of Contents

Reference facts

Application area

Medical & healthcare

Category

Published

June 26, 2024

Tags

Key takeaway
The current medical imaging techniques can only be used in a few diagnostic scenarios after the development of qualitative lesions, and they frequently include the use of radiation, among other things. Electrical impedan…
Related references

You may also like

Time-difference phantom experiment

Mathematical model of conductive fabric-based flexible pressure sensor

Electrical impedance tomography in on-chip integrated microtubular fluidic channels

Discuss your application

Want to build something like this?

Talk to our application engineers about scoping a similar setup for your team.

Get in touch with us

Headquarters

Sciospec Scientific Instruments GmbH Leipziger Str. 43b 04828 Bennewitz, Germany

Open in Google Maps

Get in touch with us

We typically reply within one business day.